The 'Eye' on Your Weld Purge 'On Site'

The Argweld® PurgEye® 1500 Site Weld Purge Monitor® is designed for the toughest on-site conditions, offering unmatched durability and precision. An IP65 rating with the lid open and IP68 with the lid closed ensures reliable performance in the most demanding environments. This robust monitor measures oxygen levels from 1,000 ppm down to 1 ppm, ensuring pristine, oxide-free welds every time.
Why Choose the Argweld PurgEye 1500 Site?
Unmatched Durability

Built to withstand the harshest conditions, ensuring reliable performance in any environment.

Precision and Control

This system provides highly accurate oxygen level measurements from 1,000 ppm down to 1 ppm, ensuring high-quality welds.

Advanced Integration

PurgeNet and PurgeLog enable seamless control of welding processes and comprehensive data logging for Quality Management.

Key Features and Benefits
  • PurgeNetĒâ Enabled: This allows the control of automatic welding systems and accessories such as visual indicators, dew point meters, and alarms for comprehensive monitoring.
  • PurgeLogĒâ Software: Facilitates data transfer for Quality Control purposes, enabling easy logging and analysis of weld purge data.
  • Internal Electro-Mechanical Pump: Ensures consistent gas flow over the sensor for accurate readings.
  • Long Life Sensor: Features a unique, fast response, solid-state sensor with minimal maintenance requirements.
  • Accurate Measurements: Measures oxygen levels from 1,000 ppm down to 1 ppm, with high accuracy down to 10 ppm.
  • Rugged Design: Housed in a virtually indestructible case, offering IP68 protection when closed and IP65 when open.
  • OLED Display: Large, sharp OLED screen for easy reading of measurements in ppm or percentage.
  • Portable and Durable: Lightweight and portable, yet extremely robust, making it perfect for on-site conditions.
  • Comprehensive Alarm System: Includes audio and visual alarms for oxygen levels outside set thresholds.
Technical Specifications
Measuring Range:
1,000 ppm to 1 ppm (accurate to 10 ppm)
Accuracy:
Ąū10 ppm
Size:
380 x 100 x 300 mm
Power Consumption:
18 W
Operating Voltage:
100-250 V AC, 50 Hz
Weight:
2.0 kg (net), 2.28 kg (with case)
Pump Flow Rate:
15 l/min
Warm-Up Time:
Less than 60 seconds
Ordering
  • Mains power lead
  • Filter with length of green tube
  • USB lead
  • User instruction booklet
  • Calibration and quality control test certificate
  • Robust carrying, presentation, and storage case
  • PurgeNetĒâ interface for smart weld purging accessories
  • PurgeNetĒâ automatic welding machine interface
  • PurgeNetĒâ traffic light visual warning accessory
  • Dew Point Sensor

HFT®ĄŊs Dew Point Sensor can be connected to the PurgEye® 1500 via PurgeNetĒâ for accurate dew point measurement, which is essential for maintaining weld integrity. This sensor is compatible with all PurgEye® monitors reading down to 1 ppm, including:

    • PurgEye® 200
    • PurgEye® Desk
    • PurgEye® 600
    • PurgEye® 1000
    • PurgEye® Site
Your Questions Answered
The PurgEye® 1500 Site is designed for extreme site conditions, such as construction sites and industries requiring pristine oxide-free welds, including aerospace, semiconductor, pharmaceutical, vacuum, biotech, food and drinks, petrochemical, oil, and gas.
Yes, it includes an integral electro-mechanical pump.
The PurgEye® Site uses a solid-state, long-life sensor with faster response times and greater stability than other monitors.
HFT® has calibration facilities in the UK, USA, Singapore, and Norway. Contact us or your nearest distributor for details and pricing.
Each instrument has shielding to prevent most forms of interference, ensuring reliable performance.
The Argweld® PurgEye® Weld Purge Monitors® should not be exposed to gas above 50ĒŠC (122ĒŠF). Contact us for information on exhaust purge gas cooling methods.
The case offers IP68 protection when sealed and IP65 when open. It is designed to be virtually indestructible.
The PurgEye® monitors measure oxygen levels within any gas, including inert gases like argon and helium and non-inert gases like nitrogen and nitrogen/hydrogen mixes.
PurgeNetĒâ controls welding power sources to switch on and off according to oxygen levels. It facilitates data transfer and connection to external devices for comprehensive monitoring and control.

DOWNLOAD OUR FULL BROCHURE

Argweld® PurgEye® 1500 Site IP68 Weld Purge Monitor®

By submitting this inquiry, you agree to subscribe to receive updates, news, and exclusive offers from Huntingdon Fusion Techniques (HFT). You can opt-out at any time.

CLIENT TESTIMONIALS

CLIENT TESTIMONIALS

STILL HAVEN’T FOUND WHAT YOU’RE LOOKING FOR?

Contact us with a question using the form here. Alternatively give us a call.
Contact Form

By submitting this inquiry, you agree to subscribe to receive updates, news, and exclusive offers from Huntingdon Fusion Techniques (HFT). You can opt-out at any time.

Copyright © Huntingdon Fusion Techniques HFT®.  All Rights Reserved..
Privacy Policy
chevron-down