Keep a Distant 'Eye' on Your Weld Purge... Up to 1 km Away!

The Argweld® PurgEye® 1000 Remote Weld Purge Monitor® is the world's first and only long-distance weld purge monitor, capable of measuring oxygen levels accurately down to 10 ppm. Equipped with an internal electro-mechanical pump and powered by battery or mains, this advanced monitor now features PurgeNet™. It allows operators to obtain instantaneous and accurate weld purge readings from up to 1 km away, ensuring optimal weld quality and preventing oxidation.
Why Choose the Argweld® PurgEye® 1000 Remote?
Long-Distance Monitoring

This method accurately measures oxygen levels up to 1 km away, making it perfect for large-scale welding projects.

Comprehensive Control

PurgeNet™ and integrated alarms ensure precise control over welding processes, preventing oxidation.

Ease of Use

Simple setup and operation with a single data cable and portable design.

Key Features and Benefits
  • Remote Sensing: The stainless-steel sensing head can be fitted onto mechanical or inflatable purging systems at the weld location, transmitting data up to 1 km away.
  • PurgeNet™ Enabled: Controls automatic welding systems and accessories such as visual indicators, dew point meters, and alarms for comprehensive monitoring and control.
  • Portable and Versatile: It is suitable for fitting to mechanical or inflatable purging systems for pipes as small as 1” (25 mm) diameter.
  • Long Life Sensor: Features a unique, fast response, solid-state sensor with minimal maintenance requirements.
  • Accurate Measurements: Accurately measures oxygen levels from 1,000 ppm down to 10 ppm.
  • Integrated Pump: Ensures a consistent gas flow over the sensor for stable readings.
  • Hand-Held Display: Provides clear and immediate readings powered by a single data cable.
  • Plug and Play: Easy to set up and operate, with quick fit and disconnect purge tube fittings.
  • Comprehensive Alarm System: Includes audio and visual alarms for oxygen levels outside set thresholds.
Technical Specifications
Measuring Range:
1,000 ppm to 10 ppm
Accuracy:
±10 ppm
Size:
150 x 90 x 170 mm
Power Consumption:
18 W
Operating Voltage:
100-250 V, 50 Hz
Weight:
1.5 Kg
Warm-Up Time:
2 minutes
Response Time:
30 seconds
Ordering
  • Hand-held display
  • Stainless steel sensor head
  • 10 m lead (longer lengths available)
  • External 12 V Power Supply Unit with international mains adaptors
  • Interface data connection cable
  • User instruction technical manual
  • Storage and presentation case
  • Calibration certificate for Quality Control Procedures and Management Systems
  • 100 m reel of outdoor cable with locking connectors
  • Fixtures for stable mounting of the sensing head
  • Dew Point Sensor

HFT®’s Dew Point Sensor can be connected to the PurgEye® 1000 via PurgeNet™ for accurate dew point measurement, essential for maintaining weld integrity. This sensor is compatible with all PurgEye® monitors reading down to 1 ppm, including:

  • PurgEye® 200
  • PurgEye® Desk
  • PurgEye® 600
  • PurgEye® 1000
  • PurgEye® Site

 

Your Questions Answered
The PurgEye® 1000 uses a solid-state sensor of a unique design, offering faster reaction times and long life at a lower cost.
This monitor is designed for applications where the sensing head needs to be placed up to 1 km from the instrument, such as pipeline welding.
Each instrument is shielded to prevent most forms of interference, ensuring reliable performance.
HFT® has recalibration facilities worldwide. Contact us or your nearest distributor for details and pricing.
The sensor head can be used in pipes with a minimum diameter of 1” (25 mm).
The sensor head housing is made from stainless steel.
HFT® can supply fixtures to mount the sensing head stably to any mechanical or inflatable pipe purging system.
The sensor head contains an electro-mechanical pump to ensure a steady exhaust gas flow across the sensor for stable measurements.
The PurgEye® monitors can measure oxygen levels within any gas, including inert gases like argon and helium and non-inert gases like nitrogen and nitrogen/hydrogen mixes.

PurgeNet™ controls welding power sources to switch on and off according to oxygen levels. It also facilitates data transfer and connection to external devices for comprehensive monitoring and control.

DOWNLOAD OUR FULL BROCHURE

Argweld® PurgEye® 1000 Remote Weld Purge Monitor®

By submitting this inquiry, you agree to subscribe to receive updates, news, and exclusive offers from Huntingdon Fusion Techniques (HFT). You can opt-out at any time.

CLIENT TESTIMONIALS

CLIENT TESTIMONIALS

STILL HAVEN’T FOUND WHAT YOU’RE LOOKING FOR?

Contact us with a question using the form here. Alternatively give us a call.
Contact Form

By submitting this inquiry, you agree to subscribe to receive updates, news, and exclusive offers from Huntingdon Fusion Techniques (HFT). You can opt-out at any time.

Copyright © Huntingdon Fusion Techniques HFT®.  All Rights Reserved..
Privacy Policy
chevron-down